1kv热缩交联电缆型中间连接
热度:110 上架时间:2023-06-02
-
0531-85812098
济南裕飞电气有限公司
型号 | 名称 | 适用电缆截面积 |
1KVRSJ-2/00 | 1KV交联电缆热缩型中间连接(二芯) | 4-6 |
1KVRSJ-2/0 | 10-16 | |
1KVRSJ-2/1 | 25-50 | |
1KVRSJ-2/2 | 70-120 | |
1KVRSJ-2/3 | 150-240 | |
1KVRSJ-2/4 | 300-400 | |
1KVRSJ-3/00 | 1KV交联电缆热缩型中间连接(三芯) | 4月6日 |
1KVRSJ-3/0 | 10-16 | |
1KVRSJ-3/1 | 25-50 | |
1KVRSJ-3/2 | 70-120 | |
1KVRSJ-3/3 | 150-240 | |
1KVRSJ-3/4 | 300-400 | |
1KVRSJ-4/00 | 1KV交联电缆热缩型中间连接(四芯,4x1,3+1) | 4-6 |
1KVRSJ-4/0 | 10-16 | |
1KVRSJ-4/1 | 25-50 | |
1KVRSJ-4/2 | 70-120 | |
1KVRSJ-4/3 | 150-240 | |
1KVRSJ-4/4 | 300-400 | |
1KVRSJ-5/00 | 1KV交联电缆热缩型中间连接(五芯,5x1,4+1,3+2) | 4-6 |
1KVRSJ-5/0 | 10-16 | |
1KVRSJ-5/1 | 25-50 | |
1KVRSJ-5/2 | 70-120 | |
1KVRSJ-5/3 | 150-240 | |
1KVRSJ-5/4 | 300-400 | |
1KVRSJZ-4/00 | 1KV油浸电缆热缩型中间连接(四芯,4x1,3+1) | 4-6 |
1KVRSJZ-4/0 | 10-16 | |
1KVRSJZ-4/1 | 25-50 | |
1KVRSJZ-4/2 | 70-120 | |
1KVRSJZ-4/3 | 150-240 | |
1KVRSJZ-4/4 | 300-400 |
项 目 | 试验项目 | 标准要求 | 试验结果 | 结 论 |
1KV终端及中间连接 | 1min工频 | 4KV | 4KV/1min | 合格 |
耐压试验 | 不闪络,不击穿 | 未闪络,未击穿 | ||
负荷循环试验 | 5h加热,3h冷却, | 由以下评定 | ||
(三次循环) | 加热时导体温度75℃ | |||
4h工频 | 2.4KV不闪络 | 2.4KV/4h | 合格 | |
耐压试验 | 不击穿 | 未闪络,未击穿 |